Smoke Detector HF-CS1
The smoke detector uses the principle of scattered light to detect whether a fire has occurred in the surrounding area. It can respond to smoke particles and convert changes in smoke concentration at the detection site into electrical signals to alarm.
Product Functions
– The fire alarm confirmation light adopts a light guide column for conduction, visible at 360°.
– Two-wire, convenient for construction wiring.
– Strong anti-interference ability, resistant to dust adhesion, electromagnetic interference, temperature influence, corrosion, and environmental light (light source) interference.
– Strong resistance to humidity and heat, able to
Product Description
Product Description
The smoke detector (hereinafter referred to as the “detector”) uses the principle of scattered light to detect whether a fire has occurred in the surrounding area. In the early stages of a fire, due to the low temperature, substances are mostly in the smoldering stage, producing a large amount of smoke. Therefore, smoke is one of the important characteristics. The smoke detector can respond to smoke particles and convert the changes in smoke concentration at the detection site into electrical signals to alarm. Not suitable for installation in places that may produce black smoke, large amounts of dust, water mist, steam, oil mist, and smoke retention.
Product Function
Fire Alarm Confirmation Light
The fire alarm confirmation light adopts a light guide column for conduction, visible at 360°.
Wiring
Two-wire, convenient for construction wiring.
Anti-interference Ability
Strong anti-interference ability, resistant to dust adhesion, electromagnetic interference, temperature influence, corrosion, and environmental light (light source) interference.
Resistance to Humidity and Heat
Strong resistance to humidity and heat, able to adapt to the requirements of different climate environments.
General
Main Power Supply
DC 24 V (DC 18 V~DC 28 V)
Indicator
1 Red
Weight
107 g
Product Dimension
φ 100.0 mm × H 55.0 mm (with base)
Detection Type
Photoelectric
HF-CS1 Specifications
Monitor Current
≤ 300 μA
Wiring
Two-wire, 1 is for L-, 3 is for L+; 2 is for R-, 4 is for R+/OUT
Alarm Current
≤ 15 mA
HF-AS1 Specifications
Monitor Current
≤ 0.3 mA
Wiring
Two-wire, 1 is for L-, 3 is for L+; 2 is for R-, 4 is for R+
Alarm Current
≤ 1.5 mA (In addressing mode, when the remote indicator light function is enabled, the alarm power consumption is ≤ 3.5 mA)
Wiring Requirements
Wiring Requirements
RVS 2*1.5 mm² Flame Retardant Wire, Max distance: 500 m